4 SAFETY FB SPECIFICATIONS
4.11 M+SF_MUTEP_R
73
4
Wrong muting sequences
Status Wrong muting sequences
8000H When muting sequence starts, i_bMutingEnable=OFF
(MS_11=ON OR MS_12=ON) AND (MS_21=ON OR MS_22=ON)
MS_11=OFFON AND MS_12=ON AND undetected MS_12=OFFON
MS_12=OFFON AND MS_11=ON AND undetected MS_11=OFFON
MS_21=OFFON AND MS_22=ON AND undetected MS_22=OFFON
MS_22=OFFON AND MS_21=ON AND undetected MS_21=OFFON
(MS_11=ON AND undetected MS_11=OFFON) AND (MS_12=ON AND undetected MS_12=OFFON)
(MS_21=ON AND undetected MS_21=OFFON) AND (MS_22=ON AND undetected MS_22=OFFON)
8011H i_bMutingEnable=OFF OR MS_11=OFF OR MS_21=ON OR MS_22=ON
8311H i_bMutingEnable=OFF OR MS_12=OFF OR MS_21=ON OR MS_22=ON
8012H MS_11=OFF OR MS_12=OFF
8021H MS_11=OFFON OR MS_12=OFFON
(MS_11=ON OR MS_12=ON) AND (MS_21=ONOFF OR MS_22=ONOFF)
(MS_11=ONOFF OR MS_12=ONOFF) AND (MS_21=ONOFF OR MS_22=ONOFF)
8014H MS_11=OFF OR MS_12=OFF OR MS_21=OFF
8314H MS_11=OFF OR MS_12=OFF OR MS_22=OFF
8122H i_bMutingEnable=OFF OR MS_11=ON OR MS_12=ON OR MS_21=OFF
8422H i_bMutingEnable=OFF OR MS_11=ON OR MS_12=ON OR MS_22=OFF
8121H MS_21=OFF OR MS_22=OFF
8112H MS_21=OFFON OR MS_22=OFFON
(MS_21=ON OR MS_22=ON) AND (MS_11=ONOFF OR MS_12=ONOFF)
(MS_11=ONOFF OR MS_12=ONOFF) AND (MS_21=ONOFF OR MS_22=ONOFF)
8114H MS_21=OFF OR MS_22=OFF OR MS_11=OFF
8414H MS_21=OFF OR MS_22=OFF OR MS_12=OFF

Other manuals for Mitsubishi Electric MELSEC iQ-R Series