46
3 POSITIONING CONTROL STARTUP
3.4 Operation Check
2. Positioning start
2. To start the positioning, double click M80 while pressing SHIFT.
3. Confirmation of Axis 1 positioning control
Check that Axis 1 moves to 100.0 mm and goes back to 0.0 mm through the Feed current value for Axis 1 in the Axis Monitor
window.
Check that the Axis feedrate for Axis 1 is equal to the command speed.
Check each monitor value and status through the Axis monitor.