APPX
Appendix 2 Parameter and Positioning Data
75
A
2. Positioning data
[Axis-1 positioning data]
[Axis-2 positioning data]
No. Operationp
attern
Control
system
Axis to be
interpolated
Acceleration
time No.
Deceleration
time No.
Positioning
address
Arc
address
Command
speed
Dwell
time
M-
code
11:CONT ABS
linear 1
1:1000 1:1000 100000.0
μm
0.0μm 2000.00
mm/min
0ms 0
20:END
ABS
linear 1
1:1000 1:1000 0.0μm 0.0μm 8000.00
mm/min
0ms 0
No. Operationp
attern
Control
system
Axis to be
interpolated
Acceleration
time No.
Deceleration
time No.
Positioning
address
Arc
address
Command
speed
Dwell
time
M-
code
10:END INC
linear 1
1:1000 1:1000 157079.6
μm
0.0μm 2000.00
mm/min
0ms 0