Reset switch (reset_in)
M+SF_EDM_R reset input
(SA\M3)
Safety refresh communication
status (SA\SD1008.0)
Muting start enable signal
(mutes_start)
M+SF_MUTES_R safety
output (SA\M1)
Start switch (start_in)
Interlock status
(SA\SD1232.0)
Interlock release request
(SA\SD1240.0)
Light curtain (SA\X4)
Contactor output (SA\Y0)
Contactor output check
(SA\X2)
Entry
detected
Reset
switch
pressed
Start
switch
pressed
Muting
started
Reset
switch
pressed
Reset
switch
pressed
Start
switch
pressed
Start
switch
pressed
Reset
switch
pressed
M+SF_EDM_R Error output
(SA\M2)
M+SF_MUTES_R
MutingEnable input (SA\M5)
Exit
confirmed
Entry
detected
Muting sensor1
(mutes_censor[1])
Muting sensor2
(mutes_censor[2])
Muting sensor3
(mutes_censor[3])
Muting sensor4
(mutes_censor[4])
Muting lamp (SA\Y2)
Muting
completed
When the light of
the light curtain is
blocked, the
M+SF_MUTES_R
safety output
(SA\M1) is turned
off, disabling the
M+SF_EDM_R.
Contact welding
detected in the
contactor 1
CCIEF
remote (1)
error
When the reset switch is
pressed, the
M+SF_MUTES_R safety
output (SA\M1) is turned on,
enabling the M+SF_EDM_R.
The contactor output remains
on even though the light of the
light curtain is blocked only
when four muting sensors
detect the workpiece at the
correct timing in the correct
sequence.
When the start switch is
pressed, the M+SF_EDM_R
safety output is turned on
and the contactor output
(SA\Y0) turns on.
When an error occurs in a safety remote I/O module,
inputs and outputs of the safety remote I/O module
are turned off.
Also, the M+SF_MUTES_R and M+SF_EDM_R are
disabled.
A safety remote I/O
module detects a
double input
discrepancy.