4 ERROR CODE LIST
4.3 MELSEC iQ-R Series Data Link Functions
115
4
-33 FFDFH ■Communication target unsupported error
The module specified as the communication target by the
network number and station number is not supported.
Check if the module specified as the communication target by a
network number and station number is supported.
-36 FFDCH ■Registry write error
Writing parameter files to the registry failed.
• Check if the standard ROM has already been shutdown.
• Reset the CPU module, or turn the power OFF and ON to
reset the C intelligent function module.
-42 FFD6H ■Close error
Communications cannot be closed.
•Retry.
• Check if the C intelligent function module is running normally.
• Reset the CPU module, or turn the power OFF and ON to
reset the C intelligent function module.
-43 FFD5H ■ROM operation error
A TC setting value was written to the CPU module during ROM
operation.
Change the TC setting value during RAM operation.
-52 FFCCH ■MELSEC iQ-R series data link function service error
MELSEC iQ-R series data link function service is disabled.
Enable the MELSEC iQ-R series data link function service with
an engineering tool.
-53 FFCBH ■Timeout value error
The specified timeout value is out of range.
Check the specified time out value.
-54 FFCAH ■I/O number error
The specified I/O number is out of range.
Check the specified I/O number.
-55 FFC9H ■Logical station number error
The specified logical station number is out of range.
Check the specified logical station number.
-56 FFC8H ■Target CPU error
The specified target CPU is out of range.
Check the specified target CPU module.
-57 FFC7H ■Access route error
The specified access route is out of range.
Check the specified access route.
-80 FFB0H ■Connection destination CPU error
The connection destination CPU is not an RCPU.
Connect an RCPU.
-81 FFAFH ■Label code mismatch error
Label assignment information of the CPU module was changed.
Acquire label information using the mdrGetLabelInfo function
again.
-82 FFAEH ■Label incorrect value error
An incorrect label name was specified.
• Non-existent label name
• A label name assigned to a device that does not support
random read/write.
• Label name assigned to a device which is specified by the
inappropriate specification method (index modification or
indirect specification)
Check the specified label name or the device specification
method.
-83 FFADH ■Size error
The number of labels exceeded the range.
Check the number of labels.
-84 FFACH ■Device specification method error
A device was specified by inappropriate specification method
(bit specification or digit specification).
Check the device specification method.
-4096 to -1 F000H to
FFFFH
*1
Q Corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network)
-4097 to -
8192
EFFFH to
E000H
*1
Refer to the following manual.
MELSEC iQ-R CC-Link IE Controller Network User's Manual (Application)
MELSEC-Q CC-Link IE Controller Network Reference Manual
-8193 to -
12288
DFFFH to
D000H
*1
Refer to the following manual.
MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
MELSEC-Q CC-Link IE Field Network Master/Local Module User's Manual
MELSEC-L CC-Link IE Field Network Master/Local Module User's Manual
-16384 to -
12289
C000H to
CFFFH
*1
Refer to the following manuals.
MELSEC iQ-R Ethernet User's Manual (Application)
-16385 to -
20480
BFFFH to
B000H
*1
Refer to the following manual.
MELSEC iQ-R CC-Link System Master/Local Module User's Manual (Application)
MELSEC-Q CC-Link System Master/Local Module User's Manual
MELSEC-L CC-Link System Master/Local Module User's Manual
28672 to
32767
7000H to
7FFFH
*1
Refer to the following manuals.
MELSEC iQ-R Serial Communication Module User's Manual(Application)
Error code Description Corrective action
Decimal Hexadec
imal