110
8 RUNNING A PROGRAM
8.5 Program Execution Type
Trigger setting
Use the event execution type detail setting.
[CPU Parameter] [Program Setting]
Operating procedure
Displayed items
"Program Setting" window
1. Click "Detailed Setting" on the
"Program Setting" window.
"Detailed Setting" window
2. Select the program name and set the
execution type to "Event".
3. Click "Detailed Setting Information".
"Event Execution Type Detailed Setting" window
4. Sets the trigger type to execute the
event execution type program.
Item Description Setting range Default
Interruption occurrence Sets the interrupt pointer used as the trigger. I0 to I15, I28 to I31, I44, I45, I48, I49, I50
to I1023
ON of Bit Data (TRUE) Sets the device used as the trigger. Page 108 Bit data ON (TRUE)
Clear Output and Current Value of
Timer
Sets that the current values of the output (Y), timer (T),
and long timer (LT) used in this program are cleared at
the execution turn of the event execution type program
that comes after the specified bit data is OFF.
Do Not Clear
Clear
Do Not Clear
Passing Time Unit Sets the time passed. When "ms" is selected: 1 to 65535ms (in
units of 1ms)
When "s" is selected: 1 to 65535s (in
units of 1s)
ms
Clear Output and
Current Value of
Timer
Sets that the current values of the output (Y), timer (T),
and long timer (LT) used in this program are cleared at
the execution turn of the event execution type program
that comes after the specified time passes.
Do Not Clear
Clear
Do Not Clear