384
26 REDUNDANT FUNCTION
26.2 System Switching
Special register
The following table shows the special register numbers for system switching and the storage status of the CPU modules in the
control system and standby system.
: Stored, : Not stored
*1 When the system switching has not been normally completed, a value is stored in this special register area of the control system.
CTRL LED and SBY LED of the redundant function module
System switching results can be checked with the CTRL LED and SBY LED on the front of the redundant function module.
SD No. Name Storage status at system switching
CPU module of the new
control system
CPU module of the new
standby system
SD1642 BACKUP/SEPARATE LED flashing cause 
SD1643 System switching cause 
SD1644 Cause of system switching failure
*1

SD1645 System switching request status from a network module of own system 
SD1646 System switching request status from a network module of the other system 
SD1648 Cause of the other system monitoring error 
SD1649 System switching cause (when the systems are successfully switched) 
SD1650 System switching instruction ID number 
Control system Standby system Standby system Control system