27 DEVICES
27.5 Link Direct Device
473
27
Difference from link refresh
The following table shows the difference between the link direct device and link refresh.
Item Link direct device Link refresh
Description method
in program
Input Jn\K4X0... X0...
Output Jn\K4Y0... Y0...
Link relay Jn\K4B0... B0...
Link register Jn\W0... W0...
Link special relay Jn\K4SB0... SB0...
Or module label
Link special register Jn\SW0... SW0...
Or module label
Access range in relation to network module All the link devices for each network module The range specified in "Refresh Setting"
Guarantee range of access data In word (16-bit) units In word (16-bit) units