682
APPX
Appendix 5 List of Special Register Areas
SD260 Number of points
assigned to bit
devices
X (L) The number of points assigned to the X device is stored in 32 bits. S (Initial)
SD261 X (H)
SD262 Y (L) The number of points assigned to the Y device is stored in 32 bits. S (Initial)
SD263 Y (H)
SD264 M (L) The number of points assigned to the M device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to M is 32K or less.
S (Initial)
SD265 M (H)
SD266 B (L) The number of points assigned to the B device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to B is 32K or less.
S (Initial)
SD267 B (H)
SD268 SB (L) The number of points assigned to the SB device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to SB is 32K or less.
S (Initial)
SD269 SB (H)
SD270 F (L) The number of points assigned to the F device is stored in 32 bits. S (Initial)
SD271 F (H)
SD272 V (L) The number of points assigned to the V device is stored in 32 bits. S (Initial)
SD273 V (H)
SD274 L (L) The number of points assigned to the L device is stored in 32 bits. S (Initial)
SD275 L (H)
SD276 S (L)
*1
The number of points assigned to the S device is stored in 32 bits. S (Initial)
SD277 S (H)
*1
SD280 Number of points
assigned to word
devices
D (L) The number of points assigned to the D device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to D is 32K or less.
S (Initial)
SD281 D (H)
SD282 W (L) The number of points assigned to the W device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to W is 32K or less.
S (Initial)
SD283 W (H)
SD284 SW (L) The number of points assigned to the SW device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to SW is 32K or less.
S (Initial)
SD285 SW (H)
SD288 Number of points
assigned to timer/
counter devices
T (L) The number of points assigned to the T device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to T is 32K or less.
S (Initial)
SD289 T (H)
SD290 ST (L) The number of points assigned to the ST device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to ST is 32K or less.
S (Initial)
SD291 ST (H)
SD292 C (L) The number of points assigned to the C device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to C is 32K or less.
S (Initial)
SD293 C (H)
SD294 LT (L) The number of points assigned to the LT device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to LT is 32K or less.
S (Initial)
SD295 LT (H)
SD296 LST (L) The number of points assigned to the LST device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to LST is 32K or less.
S (Initial)
SD297 LST (H)
SD298 LC (L) The number of points assigned to the LC device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to LC is 32K or less.
S (Initial)
SD299 LC (H)
SD300 Number of points
assigned to the
index register
Z The number of points assigned to the Z device is stored. S (Initial)
SD302 Number of points
assigned to the
long index register
LZ The number of points assigned to the LZ device is stored. S (Initial)
SD306 Number of points
assigned to the file
register
ZR (L) The number of points assigned to the ZR device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to ZR is 32K or less.
S (Initial)
SD307 ZR (H)
SD308 Number of points
assigned to
refresh devices
RD (L) The number of points assigned to the RD device is stored in 32 bits.
The number of points is stored even when the number of points
assigned to RD is 32K or less.
S (Initial)
SD309 RD (H)
No. Name Data stored Details Set by (setting
timing)

Table of Contents