748
APPX
Appendix 13 Added and Enhanced Functions
*1 This indicates the compatible software version of GX LogViewer.
*2 Step relays (BLn\Sn) can be specified with CPU Module Logging Configuration Tool or GX LogViewer.
*3 This indicates the compatible software version of CPU Module Logging Configuration Tool.
*4 Support of the program restoration information write selection of writing to the programmable controller while the CPU module is
stopped and of the file batch online change is as follows: F: 13, S: 1.040S.
*5 The firmware version of the usable RJ71GF11-T2 is "35" or later.
Setting to wait cyclic data receive after
system switching
*5
F: 18
S: 1.050C
F: 18
S: 1.050C
Page 427 Setting to wait cyclic data receive
after system switching
Event history logging restriction F: 20
S:
F: 20
S:
Page 215 Event history logging restriction
Extension of points for CC-Link IE
Controller Network
F: 27
S: 1.075D
F: 27
S: 1.075D
Page 448 Device List
Page 471 Link Direct Device
MELSEC iQ-R CC-Link IE Controller
Network User's Manual (Application)
Online Change F:
S: 1.007H
F: 04
S: 1.025B
Page 189 Online Change
Data communications between CPU
modules
F:
S: 1.007H
Page 334 MULTIPLE CPU SYSTEM
FUNCTION
Page 344 Data Communication Between
CPU Modules
Multiple CPU synchronous interrupt (I45) F:
S: 1.007H
Page 334 MULTIPLE CPU SYSTEM
FUNCTION
Inter-module synchronous interrupt (I44) F:
S: 1.007H
MELSEC iQ-R Inter-Module Synchronization
Function Reference Manual
Writing of program restoration
information
F: 20
S: 1.055H
F: 20
S: 1.055H
Page 741 Program Restoration Information
Write Selection
FB hierarchy information F: 24
S: 1.060N
F: 24
S: 1.060N
GX Works3 Operating Manual
MELSEC iQ-R series MELSECNET/H
network module
F: 23
S: 1.063R
F: 23
S: 1.063R
MELSEC iQ-R Module Configuration
Manual
MELSEC iQ-R MELSECNET/H Network
Module User's Manual (Application)
Extended SRAM cassette (NZ2MC-
2MBSE)
F:
S: 1.007H
F:
S: 1.007H
Page 78 Extended SRAM Cassette
Page 142 Device/label memory area setting
Redundant system with redundant
extension base unit
For R68WRB
F: 25
S: 1.070Y
For R66WRB-HT
F: 25
S: 1.072A
Page 370 REDUNDANT FUNCTION
MELSEC iQ-R Module Configuration
Manual
Laser displacement sensor control
module supporting the redundant system
with redundant extension base unit
F: 26
S:
M
E
LSEC iQ-R Module Configuration Manual
Program start/stop F: 27
S: 1.075D
F: 27
S: 1.075D
GX Works3 Operating Manual
Label memory read/write F: 27
S: 1.075D
F: 27
S: 1.075D
GX Works3 Operating Manual
Device/label access service processing
constant wait function
F: 27
S: 1.075D
F: 27
S: 1.075D
Page 91 Device/label access service
processing constant wait function
Copying/cutting across data logging
settings for a data setting item
F:
S:
O: 1.118X
*3
CPU Module Logging Configuration Tool
Version 1 Operating Manual (MELSEC iQ-R
Series)
System memory supports the memory
copy from control system to standby
system
F: 33
S:
Page 405 Memory Copy from Control System
to Standby System
Simple CPU communication function F: 34
S: 1.090U
F: 34
S: 1.090U
MELSEC iQ-R Ethernet User's Manual
(Application)
Added or enhanced function F: Firmware version of the CPU module
S: Software version of the engineering tool
O: Version of the other tools
Reference
Process mode Redundant mode

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-R Series

Related product manuals