270
2 PARAMETER SETTINGS
2.3 Application Settings
Ex.
Conversion table registration example
The following shows the example of conversion table registration based on the network map.
(a): For communication request message transmission, b): For response message transmission
Item Setting details of each Ethernet-equipped module when accessing from (1) to (2)
(1) Communication
request source
station (a)
(2) (3) (4)
Setting
value
(decimal)
Network Number, Station
No.
1, 12 Setting not required Setting not required Setting not required
IP Address 192.0.1.12
Item Setting details of each Ethernet-equipped module when accessing from (1) to (4)
(1) Communication
request source
station (a)
(2) Communication
relay receiving
station (b)
(3) Communication
relay sending station
(a)
(4) Communication
request destination
station (b)
Setting
value
(decimal)
Network Number, Station
No.
1, 12 1, 11 2, 22 2, 21
IP Address 192.0.1.12 192.0.1.11 192.0.2.22 192.0.2.21
Item Setting details of each Ethernet-equipped module when accessing from (2) to (1)
(1) (2) Communication
request destination
station (a)
(3) (4)
Setting
value
(decimal)
Network Number, Station
No.
Setting not required 1, 11 Setting not required Setting not required
IP Address 192.0.1.11
Item Setting details of each Ethernet-equipped module when accessing from (3) to (4)
(1) (2) (3) Communication
relay sending station
(a)
(4)
Setting
value
(decimal)
Network Number, Station
No.
Setting not required Setting not required 2, 22 Setting not required
IP Address 192.0.2.22
Item Setting details of each Ethernet-equipped module when accessing from (4) to (1)
(1) Communication
request source
station (b)
(2) Communication
relay sending station
(a)
(3) Communication
relay receiving
station (b)
(4) Communication
request destination
station (a)
Setting
value
(decimal)
Network Number, Station
No.
1, 12 1, 11 2, 22 2, 21
IP Address 192.0.1.12 192.0.1.11 192.0.2.22 192.0.2.21
RJ71
EN71
RJ71
EN71
RJ71
EN71
RJ71
EN71
CPU
module
Ethernet (Network No.1)
Ethernet (Network No.2)
(2) Communication relay receiving station (3) Communication relay sending station
(1) Communication request source station
(4) Communication request destination station
CPU
module
CPU
module
Network No.: 2
Station No.: 22
IP Address: (192. 0. 2. 22)
Network No.: 2
Station No.: 21
IP Address: (192. 0. 2. 21)
Network No.: 1
Station No.: 12
IP Address: (192. 0. 1. 12)
Network No.: 1
Station No.: 11
IP Address: (192. 0. 1. 11)