2 PARAMETER SETTINGS
2.3 Application Settings
263
2
Security
Set the security measures for access to the Ethernet-equipped module.
IP Filter Settings
Up to 32 IP addresses can be set as an IP address to be allowed or denied by the IP filter function.
Range specification and specification of the IP addresses to be excluded from the set range are also possible.
Gateway Parameter Settings
With gateway parameter settings, the Ethernet-equipped module can communicate with external devices on other Ethernet
networks via a router and gateway. One default router and up to eight routers can be set.
Set the default gateway when communicating via the default gateway. ( Page 242 Own Node Settings)
Item Description Setting range
IP Filter
Settings
IP Filter Set whether to enable the IP filter function. Not Use
•Use
(Default: Not Use)
IP Filter Settings Set the IP address to be allowed or denied. ( Page 263 IP Filter
Settings)
Disable Direct Connection with MELSOFT Set whether enable or disable direct connection to the engineering tool. Disable
Enable
(Default: Enable)
Do Not Respond to CPU Module Search Select whether to respond to the CPU module search. Do Not Respond
Respond
(Default: Respond)
Item Description Setting range
Access from IP address below Select whether to allow or deny the access from the specified IP
addresses.
Allow
•Deny
(Default: Allow)
Range Setting Select this item when specifying the IP addresses by range. (Default: Clear)
IP Address Set the IP address to be allowed or denied.
When selecting "Range Setting", enter the start IP address (left field)
and end IP address (right field) of the range.
0.0.0.1 to 223.255.255.254
(Default: Blank)
IP Address Excluded from Range When selecting "Range Setting", set the IP address to be excluded
from the set range.
Up to 32 IP addresses can be set.
0.0.0.1 to 223.255.255.254
(Default: Blank)
Item Description Setting range
Gateway Other Than Default Gateway Set to communicate with an external device on the other Ethernet via a
router.
•Use
•Not Use
(Default: Not Use)
Gateway
Information
No.1~No.8 Set the information of the gateway other than the default gateway.
( Page 264 Gateway Information)