EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R08ENCPU - List of I;O Signals; When Network Type Is Ethernet; Input Signals; Appendix 2 I;O Signals

Mitsubishi Electric MELSEC iQ-R08ENCPU
416 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
334
APPX
Appendix 2 I/O Signals
Appendix 2 I/O Signals
This section describes the I/O signals of the RJ71EN71 and the RnENCPU (network part) for the CPU module. The I/O signal
assignment of when the start I/O number of the RJ71EN71 or the RnENCPU (network part) is "0" is listed below.
List of I/O signals
The following table lists I/O signals. The device X is an input signal from the RJ71EN71 and the RnENCPU (network part) to
the CPU module. The device Y is an input signal from the CPU module to the RJ71EN71 and the RnENCPU (network part).
The I/O signals differ when the network type is Ethernet, and Q-compatible Ethernet.
When network type is "Ethernet"
Input signals
*1 This signal enabled when the network type for the P2 connector is set to "CC-Link IE Field". For details on operation of the signal, refer
to the following.
MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
Output signals
Do not use (turn on) any "use prohibited" signals as an input or output signal to the CPU module. Doing so
may cause malfunction of the programmable controller system.
For the I/O signals of the P2 connector when its network type is set to "CC-Link IE Control", refer to the
following.
MELSEC iQ-R CC-Link IE Controller Network User's Manual (Application)
For the I/O signals of the P2 connector when its network type is set to "CC-Link IE Field", refer to the
following.
MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
Device number Signal name
X0
*1
Module failure
(On: Module failure, Off: Module normal)
X1 to XE Use prohibited
XF Module ready
(On: Module operation possible, Off: Module operation not possible)
X10 to X1F Use prohibited
Device number Signal name
Y0 to Y1F Use prohibited

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-R08ENCPU