172
5 FUNCTIONS USED WITH SSCNET COMMUNICATION
5.1 Servo Parameter Management
New servo parameter is reflected to Motion CPU, therefore, the servo parameter of Motion CPU side does
not need to change.
When the axis No., servo parameter No. or servo parameter setting value is outside the setting range, "-1:
write/read error" is stored in the servo parameter write/read request flag. The setting value of servo
parameter is reflected to Motion CPU even when the write error occurred. Be sure to set within the setting
range.
When the following is set for sensing module, and servo parameter read/write is executed, "-1: write/read
error" is stored in the servo parameter write/read request flag.
• When sensing SSCNET/H head module is set at an axis No. other than the start station in 1 block.
• When a sensing extension module is set in a sensing SSCNET/H head module only configuration.
When servo parameter read/write is executed for the RIO axis of the SSCNET/H head module, "-1: write/
read error" is stored in the servo parameter write/read request flag.