EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R16MTCPU - Inverter FR-A800 Series

Mitsubishi Electric MELSEC iQ-R16MTCPU
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
268
5 FUNCTIONS USED WITH SSCNET COMMUNICATION
5.8 Compatible Devices with SSCNETIII(/H)
Inverter FR-A800 series
FR-A800 series can be connected via SSCNET/H by using built-in option FR-A8AP and FR-A8NS.
System configuration
The system configuration using FR-A800 series is shown below.
Parameter setting
To connect FR-A800 series, set the following in the servo network setting. (Page 64 Servo network setting)
Set "SSCNET/H" for communication type in SSCNET setting.
Set the amplifier model in amplifier setting to "FR-A800-1", or "FR-A800-2".
R64MTCPU: 2 lines (Up to 64 axes (Up to 32 axes/line))
R32MTCPU: 2 lines (Up to 32 axes (Up to 16 axes/line))
R16MTCPU: 1 line (Up to 16 axes)
Servo amplifier
MR-J4(W)-B
Inverter
FR-A800 series
Servo amplifier
MR-J4(W)-B
Inverter
FR-A800 series
SSCNETµ/H(CN1)
SSCNETµcable
MR-J3BUSM(-A/-B)
SSCNETµ/H(CN2)
Motion CPU module
RMTCPU

Table of Contents

Related product manuals