294
6 COMMUNICATION FUNCTIONS
6.2 Security Function
6.2 Security Function
The theft, tampering, incorrect operation, and illegal execution of customer assets stored on personal computers, or customer
assets inside modules in the MELSEC iQ-R series system due to unauthorized access by a third party is prevented. Use each
security function for the purposes below.
File password
This function is used to protect the data of Motion CPU by registering a password for the file in the Motion CPU.
Password authentication is required when reading/writing data.
There are two types of password, "Read protect" and "Write protect". Both settings can be specified for a single data item.
Data protected by file password
The data protected file password are shown below.
Data protection
target
Purpose Security function Reference
Project Prevents unauthorized program (program file units) viewing.
(Uses a security key.)
Security key authentication
function
Page 296 Software security key
authentication
Motion CPU Prevents unauthorized program execution. (Uses a security key.)
Prevents unauthorized file reading/writing. (Uses a password.) File password function Page 294 File password
Recognizes the IP address of external devices via a
PERIPHERAL I/F and blocks access with unauthorized IP
addresses.
IP filter function Page 301 IP filter function
Data type Data name Protected content
Motion SFC parameter Motion SFC parameter Motion SFC parameter
Motion SFC program Motion SFC program Motion SFC program
Servo program Servo program Servo program and program allocation
R series common parameter System parameter System parameter
CPU parameter CPU parameter
Module parameter Module parameter
Servo parameter Axis 1 to axis 64 servo parameter
Axis 601 to axis 608 servo parameter (sensing module)
Servo parameter (up to 72 axes)
Synchronous control parameter Command generation axis parameter Command generation axis parameter
Synchronous encoder axis parameter Synchronous encoder axis parameter
Servo input axis parameter Servo input axis parameter
Axis 1 to axis 64 Synchronous control parameters (up to 64 axes)
Machine control parameter Machine common parameter Machine common parameter
Machine parameter Machine parameter
Cam data Cam data Cam data (up to 1024 data items)
Label/structured data types Label/structured data types settings Label/structured data types settings
(Excluding label allocation information)
Device comment Device comment Device comment