6 COMMUNICATION FUNCTIONS
6.4 Communication Function via PERIPHERAL I/F
307
6
Connection via HUB
Between the Motion CPU and MT Developer2 can be connected via HUB.
Setting in Motion CPU side
Set the items on the IP address setting as shown below.
[R Series Common Parameter] [Motion CPU Module] [Module Parameter] "IP Address Setting"
■Enabling the parameters of Motion CPU
Using Ethernet direct connection or USB/RS-232 connection, write the settings in parameter to the Motion CPU by selecting
[Online] [Write to Motion] in MT Developer2. After writing the parameter settings, power the Multiple CPU system OFF to
ON or reset using the RUN/STOP/RESET switch so that the parameters become valid. Connect directly with an Ethernet
cable between the personal computer and Motion CPU to write the parameters using the Ethernet cable. (Page 304
Direct connection)
1. Set the Motion CPU IP address. (Default IP
address: 192.168.3.39) Change the IP address if
required. No need to set "Subnet Mask Pattern"
and "Default Router IP Address".
PERIPHERAL I/F
Panel computer
Ethernet cable
(straight cable)
Ethernet cable
(straight cable)
MT Developer2
HUB