6 COMMUNICATION FUNCTIONS
6.5 Vision System Connection Function
315
6
Vision system parameter setting
This section describes the setting items for vision system parameter system.
When writing the vision system parameters into the Motion CPU, execute one of the following.
• Select the menu bar [Check/Convert] [Vision System Parameter Check].
• Click [Convert] button of Ethernet communication line setting screen or vision program operation setting
screen.
Ethernet Communication Line Setting
Set the parameters related to the vision system Ethernet communication.
[Motion CPU Common Parameter] [Vision System Parameter] "Ethernet Communication Line"
■Vision System (camera) No. (Not necessary to set)
This number (1 to 32) is used by the vision system dedicated function to identify the vision system.
■IP Address
Set the IP address set for each vision system.
Item Setting Range
Vision system No. 1 to 32
IP address 0.0.0.1 to 255.255.255.254
Port No. For telnet communication 1 to 65535
*: Cannot use 21, 68, 80, 502, 1069, 1070, 1212, 2222, 44818, 50000
For TCP/IP communication
User name Up to 15 characters
Password Up to 15 characters
Status storage device Word device
Error flag Bit device