6 COMMUNICATION FUNCTIONS
6.5 Vision System Connection Function
315
6
Vision system parameter setting
This section describes the setting items for vision system parameter system.
When writing the vision system parameters into the Motion CPU, execute one of the following.
Select the menu bar [Check/Convert] [Vision System Parameter Check].
Click [Convert] button of Ethernet communication line setting screen or vision program operation setting
screen.
Ethernet Communication Line Setting
Set the parameters related to the vision system Ethernet communication.
[Motion CPU Common Parameter] [Vision System Parameter] "Ethernet Communication Line"
Window
Displayed items
Vision System (camera) No. (Not necessary to set)
This number (1 to 32) is used by the vision system dedicated function to identify the vision system.
IP Address
Set the IP address set for each vision system.
Item Setting Range
Vision system No. 1 to 32
IP address 0.0.0.1 to 255.255.255.254
Port No. For telnet communication 1 to 65535
*: Cannot use 21, 68, 80, 502, 1069, 1070, 1212, 2222, 44818, 50000
For TCP/IP communication
User name Up to 15 characters
Password Up to 15 characters
Status storage device Word device
Error flag Bit device