7 DIGITAL OSCILLOSCOPE
7.1 Features
337
7
7 DIGITAL OSCILLOSCOPE
7.1 Features
Analysis is possible with high-accuracy sampling.
Sampling is possible in cycles as short as 0.222ms. Sampling is performed without missing specified control data changes. By
reading the sampling result with the MT Developer2 digital oscilloscope and outputting to a waveform, the identification of
system startup and the cause of trouble can be analyzed with high accuracy.
Offline sampling is possible with the personal computer.
By writing a setting data file necessary for sampling to the Motion CPU standard ROM or to an SD memory card beforehand,
sampling can even be performed offline. This allows sampling to be performed even in environments where there is no
personal computer or where the cable connected to the personal computer is damaged. Furthermore, sampling results output
and saved to a specified location can be checked and analysed directly without using the MT Developer2 digital oscilloscope.
7.2 Function Overview
With the digital oscilloscope function, data can be sampled in specified cycles, and sampling results can be saved to the
standard ROM or to an SD memory card.