384
APPENDICES
Appendix 1 Error Codes
0C85H Sensing module
connection configuration
warning
The connection number in 1 block differs from the
system setting.
The number of servo amplifier or module connected
between Motion CPU and sensing module is over the
specified number.
Check the connection status of the sensing module.
Review the connection configuration of the sensing
module.
0ED0H Boot log create error Boot log file cannot be created. Delete unnecessary file in standard ROM. (Confirm the
free space.)
0ED1H Boot log copy error Failed to copy to SD memory card of boot log file. Delete unnecessary file in SD memory card. (Confirm the
free space.)
0EE0H Machine control setting
data warning
The setting data is outside the range during machine
control.
Confirm the detail code and set the adequate value of
parameter within the range. (For the detail code, refer to
MELSEC iQ-R Motion Controller Programming
Manual (Machine Control).)
0EE1H Speed control 10
multiplier setting for
degree warning of
machine structuring axis
Axis which is valid at speed control 10 multiplier setting
for degree axis exists in machine configuration axis.
Set invalid for speed control 10 multiplier setting for
degree axis of machine configuration axis.
0EF0H Add-on function warning Warning has been occurred in add-on function. Check the detail information and refer to instruction
manual of add-on library that supported file name.
0EF1H Add-on license warning Warning occurred in add-on license check. Confirm the detailed code. (For the detailed code, refer to
MELSEC iQ-R Motion Controller Programming
Manual (Common).)
Error
code
Error name Error details and cause Corrective action