2 COMMON PARAMETERS
2.2 R Series Common Parameter
55
2
CPU parameter
Set the operational details for the Motion CPU's functions. Also, regarding the overall system, settings for which verification
between CPUs is not necessary are also stored in these parameters.
[R Series Common Parameter] [Motion CPU Module] [CPU Parameter]
Item Setting range Default value
Name setting Title setting Up to 32 characters No setting
Comment setting Up to 256 characters No setting
Operation
related setting
RUN contact X0 to X2FFF No setting
Output mode setting of STOP to RUN Output the output (Y) status before STOP/
Clear the output (Y) (output is 1 scan later)
Output the output (Y)
status before STOP
Module synchronous setting Synchronize/Do not synchronize Synchronize
Device related
setting
Device points Bit device (M, B, F)/Word device (D, W, #) Page 84 Device
points setting
Latch setting Up to 32 settings No setting
RAS setting Error detections
setting
Module verify error Detect/Not detected Detect
Over execute
time of Motion
CPU fixed scan
process
Over execute time
(operation cycle over)
Detect/Not detected Not detected
Over fixed scan data
send section
Detect/Not detected Not detected
CPU module
operation setting at
error detected
Instruction execution error module I/O No.
specification incorrect
Stop/Continue Stop
Memory card access error Stop/Continue Stop
Module verify error Stop/Continue Stop
Over execute
time of Motion
CPU fixed scan
process
Over execute time
(operation cycle over)
Stop/Continue Stop
Over fixed scan data
send section
Stop/Continue Stop
Synchronous interrupt execution interval
error (CPU module)
Stop/Continue Stop
Event history setting Save destination SD memory card/Standard ROM Standard ROM
Set save volume of per file 1 to 2048[k bytes] 128[k bytes]
I/O assignment
setting
CPU module
operation setting at
error detected
Slot
0 to 63
Major: Stop, Moderate: Stop/
Major: Stop, Moderate: Continue/
Major: Continue, Moderate: Continue
Major: Stop,
Moderate: Continue