296
15 DATA COMMUNICATIONS USING USER FRAMES
15.3 Program for Data Reception with User Frame
Registration contents in user frame
Program example when setting with Engineering tool
Program example
For information on the module FB to be used, refer to the following manual.
MELSEC iQ-R Serial Communication Module Function Block Reference
User frame No. Registered code Registered data content
3E8H/8001H 02H, 51H, 20H, 0AH, 3BH STX, Q, (SP), Station No. of target device, ;
3E9H/8002H 02H, 41H, 3BH STX, A, ;
6H 06H ACK
15H 15H NAK
41BH/8005H 03H, FFH, F0H ETX, Sum check code
Category Label name Description Device
Module label C24_1 Target module
C24_1.stnCH1.bSet_Req_ReceptionRead CH1 Reception data read request X3
C24_1.stnCH1.bSts_ReceptionAbnormalDetection CH1 Reception abnormal detection X4
C24_1.stnCH1.uResult_ReceiveUserFrame_D CH1_Receive user frame (nth) U0\G603
Label to be defined Define the global label as shown below.