444
27 TROUBLESHOOTING
27.1 Checking Module Status
Checking transmission setting
Details of transmission settings can be monitored.
Window
Displayed items
Item Description
Operation setting Independent, Interlink
Data bit 7, 8
Parity bit None, Yes
Odd/even parity Odd, Even
Stop bit 1, 2
Sum check code None, Yes
Online change Disable, Enable
Setting change Disable, Enable
Test mode setting No specification, Hardware test, Self-loopback test
Communication speed setting 1200, 2400, 4800, 9600 ,14400 ,19200 ,28800 ,38400, 57600, 115200, 230400 (bps)
Communication protocol MELSOFT Connection, MC protocol (format 1 to 5), Nonprocedural protocol, Bidirectional protocol, For interlink
operation setting
The communication protocol is valid when the test mode setting is set to "No specification".
Station number setting 0 to 31