1 FUNCTIONS
1.1 EtherNet/IP Communication Functions
25
1
Setting method
For Class1 instance communications, set the originator and target on the RJ71EIP91 on the scanner side.
■Originator (on scanner side) settings
Under "Basic Setting" in the engineering tool, set the IP address, subnet mask, and default gateway of the RJ71EIP91.
[Navigation window] Ö [Parameter] Ö [Module Information] Ö [RJ71EIP91] Ö [Basic Setting]
For details on the setting window, refer to the following.
Page 44 Basic Setting
■Target (on adapter side) settings
After registering the EtherNet/IP device with EtherNet/IP Configuration Tool, set the adapter side for each connection.
For details on registering EtherNet/IP devices, refer to the following.
Page 94 Procedure for Registering EtherNet/IP Devices
Select the EtherNet/IP device in the network configuration settings Ö [Device] Ö [Properties] Ö [Connections] tab
For details on the setting window, refer to the following.
Page 79 [Connections] tab
(1) Input data size
(2) Trigger type
(3) RPI
(4) Output data size
(5) RPI