9 CREATING A HARDWARE LOGIC
9.2 Multi Function Counter Block
Cam switch output terminal
In the sixth section in a 32-bit multi function counter block detail window, one cam switch output terminal ("Cam Output") is
arranged by default. No cam switch output terminal is arranged in a 16-bit multi function counter block.
The arranged cam switch output terminal is linked with the cam switch block.
The signals input to the cam switch output terminal can be output from the "Cam Output" terminal in the multi function counter
block arranged in the hardware logic outline window.
Output
The following table shows the output of the cam switch output terminal.
*1 The cam switch block and the cam switch output terminal are linked automatically and the link cannot be deleted.
Variable name Data type Linkable block Valid range Description
Cam Output Bit Cam switch
*1
0, 1 Outputs the High/Low states of the "Cam Output"
terminal of a multi function counter block in the
hardware logic outline window.