EasyManua.ls Logo

Mitsubishi Electric MELSEC-L Series LD40PD01 - Page 182

Mitsubishi Electric MELSEC-L Series LD40PD01
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
180
10 BLOCK LINK EXAMPLES
10.2 One-shot Timer
Operation
The following shows operation of the one-shot timer when a trigger signal is input.
No. Description
(1) When a signal is input to the input terminal 0, the signal is output from the output terminal 1 of the input signal event detection block. The output signal
turns the PRESET terminal of the counter timer block to High and to Low, performing the preset. (Count value: 0)
The signal output from the output terminal 0 of the input signal event detection block turns the RUN terminal of the counter timer block to High, starting
counting per clock cycle. In addition, outputs from the output terminal 0 start.
(The RUN terminal has a lower priority than the PRESET terminal. Thus, counting per clock cycle starts after the preset.)
(2) When the count value becomes 100, the Output terminal of the compare block turns to High. The event output terminal 0, event input terminal 0, and
the STOP terminal of the counter timer block turn to High in the described order. In addition, outputs from the output terminal 0 stop.
(3) When the STOP terminal of the counter timer block turns to High, counting per clock cycle stops.
1• • • •100
(2)
High
Low
1 1• • • •100 1 1• • • •100 1 1,2,3• • •0
High
Low
High
Low
High
Low
High
Low
(1)
High
Low
High
Low
High
Low
High
Low
(3)
Count value
Controlled by the flexible high-speed I/O control module
Input terminal 0
Output 0 of the input signal event
detection block
Output 1 of the input signal event
detection block
PRESET terminal of the counter
timer block
RUN terminal of the counter
timer block
STOP terminal of the counter
timer block
Output terminal 0
Event input terminal 0
Output terminal of the compare
block

Table of Contents

Related product manuals