EasyManua.ls Logo

Mitsubishi Electric MELSEC-L Series LD40PD01 - 6.5 Example of External Wiring with External Output Terminals

Mitsubishi Electric MELSEC-L Series LD40PD01
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
54
6 INSTALLATION AND EXTERNAL WIRING
6.4 Example of External Wiring Between the Flexible High-speed I/O Control Module and an Encoder
Example of external wiring with a line driver (equivalent to
AM26LS31) encoder
IN 0_DIF
4.1k270240
820
4.1k270240
820
4.1k270240
820
IN 0_5V
IN 0_24V
IN 0_COM
IN 1_DIF
IN 1_5V
IN 1_24V
IN 1_COM
IN 2_DIF
IN 2_5V
IN 2_24V
IN 2_COM
B18
A19
B19
A18
B16
A17
B17
A16
B14
A15
B15
A14
A
A
B
B
Z
Z
E
Flexible high-speed I/O control module
IN 0
(Phase A input)
IN 1
(Phase B input)
IN 2
(Phase Z input)
Shielded twisted pair cable
Encoder
Phase A
input
Phase B
input
Phase Z
input

Table of Contents