8 FUNCTIONS OF THE CONFIGURATION TOOL
8.7 Windows for Creating the Hardware Logic
83
8
Copying a block
A block arranged in the hardware logic outline window can be copied by block unit. The setting values can be changed by
block in a batch and an arranged block can be copied.
Procedure of copying a block
The following describes the procedure of copying a block.
1. Click the block to be copied.
The block is highlighted (displayed in yellow) and selected.
2. Right-click the block and select "Copy" from the context menu.
Users can also copy multi function counter blocks by right-clicking a multi function counter block name
(Counter_) in the tree of the Navigation window and selecting "Copy" from the context menu.
Select [Edit] [Copy] to perform the same operation as selecting "Copy" from the context menu.
Operation details and restrictions
Multiple blocks cannot be copied at a time. Only a single block can be copied.
The link between the block to be copied and other blocks is not copied. However, when the block to be copied is a multi
function counter, link information in the multi function counter block detail window is also copied.
The following table shows which main blocks can be copied.
*1 This indicates a section in the hardware logic outline window.
Section
*1
Target block Copying Item to be copied
1 External input block Possible Setting values of the block
Y device terminal
OUT terminal
Impossible
2 Parallel encoder block
SSI encoder block
Possible Setting values of the block
3 Multi function counter block Possible Setting values in the multi function counter block detail window (the setting
value of User Address is not included) and links
Link between Event terminals of a multi function counter block in the hardware
logic outline window (the links across blocks cannot be copied.)
4 Logical operation block Possible The setting value of the block
5 External output block Possible Setting values of the block
SI device terminal Impossible