86
8 FUNCTIONS OF THE CONFIGURATION TOOL
8.8 Library Function
Operation details and restrictions
Multiple blocks cannot be exported at a time. Only a single block can be exported.
The link between the block to be exported and other blocks is not exported. However, when the block to be exported is a
multi function counter, the link information in the multi function counter block detail window and the link between Event
terminals of a multi function counter block in the hardware logic outline window are also exported.
The following table shows which main block can be exported.
*1 This indicates a section in the hardware logic outline window.
Section
*1
Target block Export Item to be exported
1 External input block
Y device terminal
OUT terminal
Impossible
2 Parallel encoder block
SSI encoder block
Possible Setting values of the block
3 Multi function counter block Possible Setting values in the multi function counter block detail window (the setting
value of User Address is not included) and links
Link between Event terminals of a multi function counter block in the hardware
logic outline window (the links across blocks cannot be exported.)
4 Logical operation block Impossible
5 External output block
SI device terminal
Impossible