164
(b) Communications using an ASCII code
Command format (from the connected device to the E71)
Response format (from the E71 to the connected device)
Text (20 words)
(10 words)
(L) (H) (L)
---
(H) (L)
--
(H)
-
(H) (L)
--
34
H
31
H
33
H
36
H
37
H
39
H
39
H
41
H
42
H
Start address
Subheader
Data length
(L) (H) (L)
---
(H)
-
30
H
32
H
36
H
30
H
00
H
00
H
00
H
00
H
00
H
(H) (L)
12
H
78
H
Physical address Logical address
Random access buffer
2689
H
( 9865)
3E7F
H
(15999)
1
H
( 1)
9
H
( 9)
17FF
H
(6143)
ASCII-binary conversion
00
H
00
H
41
H
32
H
35
H
38
H
41
H
42
H
43
H
43
H
2680
H
( 9856)
2681
H
( 9857)
2682
H
( 9858)
56
H
9A
H
34
H
BC
H
0
H
( 0)
2
H
( 2)
9A
H
BC
H
End code
Subheader
45
H
32
H
30
H
30
H