CHAPTER 7 COMMUNICATION PROCEDURE
7
7.1 Setting Parameters Required for Communications
7.1.4 Open Setting
● Note the following points when setting port numbers.
: Can be set, : Cannot be set
● Consult with the network administrator for setting the port numbers of the E71 and the connected device and the IP
address of the connected device.
Connection status Description
Communication
protocol
TCP/IP UDP/IP
When connecting multiple connected devices, set multiple
own station port numbers.
When connecting multiple connected devices, set a single
own station port number. (However, connections need to be
opened by the number of connections.) This setting cannot
be configured when the own station is Unpassive.
When connecting multiple ports on a connected device, set
multiple port numbers of the E71.
When connecting multiple ports on a connected device, set
a single port number of the E71. (However, connections
need to be opened by the number of connections.) This
setting cannot be configured when the own station is
Unpassive.
When connecting the same port on a connected device, set
multiple port numbers of the E71. (However, connections
need to be opened by the number of connections.)
Multiple ports can be set for the same port on a connected
device and on the E71 only when paring open has been set.
E71
Connected device
Connected device
E71
Connected device
Connected device