6 - 90
6 POSITIONING CONTROL
(5) Motion SFC program
Motion SFC program for which executes the servo program is shown below.
Fixed-pitch feed using 3 axes linear interpolation
Fixed-pitch feed using 3 axes linear interpolation
SET M2042
FEED-3
Axis 1, 50000pulse
Axis 2, 40000pulse
Axis 3, 30000pulse
Speed
PX000*M2415*M2435*M2455
END
!PX000
Positioning speed . . . . . . . . . . . . . . . 10000[pulse/s]
P0
P0
Fixed-pitch feed using
3 axes linear interpolation
Turn on all axes servo ON command.
Wait until PX000, Axis 1 servo ready, Axis 2 servo ready
and Axis 3 servo ready turn on.
Axis used . . . . . . . . . Axis 1, Axis 2, Axis 3
Axis 1 . . . 500000[pulse]
Axis 2 . . . 400000[pulse] Travel value . . . . . .
1000pulse/s
Axis 3 . . . 300000[pulse]
After fixed-pitch feed completion,
PX000 is ON : Fixed-pitch feed start again.
PX000 is OFF : Motion SFC program end.
[G10]
[F10]
[K320]
[G20]
(Note): Example of the above Motion SFC program is started using the automatic start or sequence program.