APP - 112
APPENDICES
APPENDIX 6.4 Optical hub unit
QDS
Ver.!
The SSCNET /H Compatible Optical Hub Unit (MR-MV200) is a unit that enables the
branching of SSCNET
/H communication on 1 line (3 branches for 1 input).
SSCNET
/H communication can be branched by installing an optical hub unit in a
SSCNET
/H system. The optical hub unit is compatible with all slave equipment
(servo amplifiers etc.) that supports SSCNET
/H communication.
Setting the optical hub unit station settings on Motion CPUs and MT Developer2 is not
required.
The power supply of equipment connected to the optical hub unit can be turned
OFF/ON (Disconnect/Reconnect) during operation.
(1) Restrictions on SSCNET communication
Set the communication type to "SSCNET /H" for the SSCNET setting
connecting the optical hub unit.
SSCNET
/H communication equipment set in MT Developer2 can be connected.
There are no restrictions on connection order or connection position.
The servo amplifiers and SSCNET
/H compatible equipment that can be used
with the optical hub unit are shown below.
SSCNET setting
Servo amplifier
SSCNET
/H compatible
equipment
MR-J4(W)- B MR-J3(W)- B
SSCNET /H
SSCNET
: Available : Not available
Ver.!
: Refer to Section 1.3 for the software version that supports this function.