545
CHAPTER 10 TROUBLESHOOTING
10
10.4 Checking the Error Description with the CC IE Control Diagnostics
10.4.2 Cable insertion error
10.4.2 Cable insertion error
The following explains the procedures to be taken when OUT and IN of a cable are connected incorrectly.
(1) When a programming tool connected station is normally operating
Select the own station.
A communication error has occurred between the OUT-side of the station
No.2 and the IN-side of the station No.4.
Select the faulty station (station No.2).
An error has occurred in the station No.2.
Click the error details button.
The Error Factor field indicates that a cable has not been inserted into
the correct port.
Take corrective actions according to the troubleshooting.
Control
station
No.1
Normal station
No.2
Normal station
No.4
Normal station
No.3
Selected
station
Control station
No.1
Normal
station
No.2
Normal station
No.4
Normal station
No.3
Selected
station