97
CHAPTER 4 FUNCTIONS
4
4.2 Transient Transmission Function
4.2.1 List of dedicated instructions and transient transmission range
4.2.1 List of dedicated instructions and transient transmission
range
(1) List of link dedicated instructions and transient transmission range
(a) List of link dedicated instructions
The table below shows the link dedicated instructions that can be used for CC-Link IE Controller Network
modules.
For how to use link dedicated instructions, refer to the following.
Page 324, CHAPTER 9
Instruction
*1
Description
Target (another station)
Target network
Target station
type
READ
SREAD
Reads data from a device of a programmable controller on another
station. (In units of words)
• CC-Link IE
Controller
Network
• CC-Link IE Field
Network
• MELSECNET/H
• MELSECNET/10
• Ethernet
•QCPU
•RCPU
•LCPU
•QnACPU
WRITE
SWRITE
Writes data to a device of a programmable controller on another station.
(In units of words)
*3
• CC-Link IE
Controller
Network
• CC-Link IE Field
Network
• MELSECNET/H
• MELSECNET/10
• Ethernet
•QCPU
•RCPU
•LCPU
•QnACPU
REQ
Makes the following transient request to a programmable controller on
another station.
• Remote RUN/STOP
*2
• Clock data reading/writing
*3
• CC-Link IE
Controller
Network
• CC-Link IE Field
Network
• MELSECNET/H
• MELSECNET/10
• Ethernet
•QCPU
•RCPU
•LCPU
•QnACPU
*1
Command
READ
Word device
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
Channel 9
Channel 10
2594
Word device
2594
CPU module
CPU module
CC-Link IE Controller
Network module
Network
module
*1
Command
WRITE
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
Channel 9
Channel 10
Word device
361
CPU module
CPU module
CC-Link IE Controller
Network module
Network
module
Command
REQ
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
STOPSTOP
CPU module CPU module
CC-Link IE Controller
Network module
Network
module