EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q Series - List of Instruction Conversion from Anscpu to QCPU (Dedicated Instructions)

Mitsubishi Electric MELSEC-Q Series
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 REPLACEMENT OF PROGRAM
7 - 19
7.2.2 List of instruction conversion from AnSCPU to QCPU (Dedicated instructions)
ï‚¡: Automatic conversion ï‚´: Manual change required
Description
AnSCPU QnUCPU
Reference
Instruction name Instruction name Conversion
COS
-1
operation on floating point data
ACOS ACOS ï‚¡
Floating point data addition ADD E+ ï‚¡
Conversion from hexadecimal BIN to ASCII ASC ASC ï‚¡
SIN
-1
operation on floating point data
ASIN ASIN ï‚¡
TAN
-1
operation on floating point data
ATAN ATAN ï‚¡
BCD type COS
-1
operation
BACOS BACOS ï‚¡
BIN 16-bit dead band controls BAND BAND ï‚¡
BCD type SIN
-1
operations
BASIN BASIN ï‚¡
BCD type TAN
-1
operations
BATAN BATAN ï‚¡
Conversion from 4-digit BCD to decimal ASCII BCDDA BCDDA ï‚¡
BCD type COS operations BCOS BCOS ï‚¡
BCD 8-digit square roots BDSQR BDSQR ï‚¡
Conversion from BIN 16-bit to decimal ASCII BINDA BINDA ï‚¡
Conversion from BIN 16-bit to hexadecimal ASCII BINHA BINHA ï‚¡
Block move between extension file registers BMOVR OUT SM1255 ï‚´ Section 7.2.3 (4)
Forced end of FOR to NEXT instruction loop BREAK BREAK ï‚¡
BCD type SIN operations BSIN BSIN ï‚¡
BCD 4-digit square roots BSQR BSQR ï‚¡
BCD type TAN operations BTAN BTAN ï‚¡
Data linking in byte units BTOW BTOW ï‚¡
Block exchange between extension file registers BXCHR OUT SM1255 ï‚´ Section 7.2.3 (4)
Consecutive display of the same character
CC1 OUT SM1255 ï‚´ Section 7.2.3 (11)
CC2 OUT SM1255 ï‚´ Section 7.2.3 (11)
Changing the character color
CCDSP OUT SM1255 ï‚´ Section 7.2.3 (11)
CCDSPV OUT SM1255 ï‚´ Section 7.2.3 (11)
Special format failure checks CHK OUT SM1255 ï‚¡
Section 7.2.3 (3),
(4)
Changing check format of CHK instruction CHKEND OUT SM1255 ï‚¡ Section 7.2.3 (4)
Displaying numerals CIN0 to CIN9 OUT SM1255 ï‚´ Section 7.2.3 (11)
Displaying letters of the alphabet CINA to CINZ OUT SM1255 ï‚´ Section 7.2.3 (11)
Clearing display of designated area CINCLR OUT SM1255 ï‚´ Section 7.2.3 (11)
Displaying "-" (hyphen) CINHP OUT SM1255 ï‚´ Section 7.2.3 (11)
Displaying "-" (minus) CINMP OUT SM1255 ï‚´
Displaying "." (period, decimal point) CINPT OUT SM1255 ï‚´
Displaying spaces CINSP OUT SM1255 ï‚´ Section 7.2.3 (11)
Clearing the display area CLS OUT SM1255 ï‚´ Section 7.2.3 (11)
Clearing the VRAM area CLV OUT SM1255 ï‚´ Section 7.2.3 (11)
Setting the display mode CMODE OUT SM1255 ï‚´ Section 7.2.3 (11)
Transferring canvas data to the VRAM area CMOV OUT SM1255 ï‚´ Section 7.2.3 (11)
Setting normal display for characters CNOR OUT SM1255 ï‚´ Section 7.2.3 (11)
Displaying the cursor COFF OUT SM1255 ï‚´ Section 7.2.3 (11)
Designating the character display color COLOR OUT SM1255 ï‚´ Section 7.2.3 (11)
Reading device comment data COMRD COMRD ï‚¡
Displaying the cursor
CON1 OUT SM1255 ï‚´ Section 7.2.3 (11)
CON2 OUT SM1255 ï‚´ Section 7.2.3 (11)
COS operations on floating decimal point data COS COS ï‚¡
Displaying a canvas screen CPS1 OUT SM1255 ï‚´ Section 7.2.3 (11)
Changing the VRAM display address CPS2 OUT SM1255 ï‚´ Section 7.2.3 (11)
Consecutive display of the same character
CR1 OUT SM1255 ï‚´ Section 7.2.3 (11)
CR2 OUT SM1255 ï‚´ Section 7.2.3 (11)
Switching between normal and highlighted display for
characters
CRDSP OUT SM1255 ï‚´ Section 7.2.3 (11)
CRDSPV OUT SM1255 ï‚´ Section 7.2.3 (11)

Table of Contents

Other manuals for Mitsubishi Electric MELSEC-Q Series

Related product manuals