7 REPLACEMENT OF PROGRAM
7 - 20
Setting highlighted display for characters CREV OUT SM1255 ï‚´ Section 7.2.3 (11)
Scrolling the screen
CSCRD OUT SM1255 ï‚´ Section 7.2.3 (11)
CSCRU OUT SM1255 ï‚´ Section 7.2.3 (11)
Conversion from decimal ASCII to BCD 4-digit data DABCD DABCD ï‚¡
Conversion from decimal ASCII to BIN 16-bit data DABIN DABIN ï‚¡
Reading clock data DATERD DATERD ï‚¡
Writing in clock data DATEWR DATEWR ï‚¡
BIN 32-bit dead band controls DBAND DBAND ï‚¡
Conversion from BCD 8-digit to decimal ASCII data DBCDDA DBCDDA ï‚¡
Conversion from BIN 32-bit to decimal ASCII data DBINDA DBINDA ï‚¡
Conversion from BIN 32-bit data to hexadecimal
ASCII data
DBINHA DBINHA ï‚¡
Conversion from decimal ASCII to BCD 8-digit data DDABCD DDABCD ï‚¡
Conversion from decimal ASCII to BIN 32-bit data DDABIN DDABIN ï‚¡
Conversion from floating point radian to angle DEG DEG ï‚¡
Conversion from BIN 32-bit to floating point data DFLOAT DFLT ï‚¡
Conversion from hexadecimal ASCII to BIN 32-bit
data
DHABIN DHABIN ï‚¡
Conversion from floating point to BIN 32-bit data DINT DINT ï‚¡
Dissociation of random data DIS NDIS ï‚¡
Division of floating decimal point data DIV E/ ï‚¡
Upper and lower limit controls for BIN 32-bit data DLIMIT DLIMIT ï‚¡
Direct output DOUT OUT ï‚¡
Direct Reset DRST RST ï‚¡
32-bit data searches DSER DSER ï‚¡
Direct Set DSET SET ï‚¡
Conversion from BIN 32-bit to character string DSTR DSTR ï‚¡
Bit tests DTEST DTEST ï‚¡
Conversion from character string to BIN 32-bit data DVAL DVAL ï‚¡
Zone control for BIN 32-bit data DZONE DZONE ï‚¡
Displaying characters
EPR OUT SM1255 ï‚´ Section 7.2.3 (11)
EPRN OUT SM1255 ï‚´ Section 7.2.3 (11)
Writing characters to the VRAM
EPRV OUT SM1255 ï‚´ Section 7.2.3 (11)
EPRNV OUT SM1255 ï‚´ Section 7.2.3 (11)
Exponent operations on floating decimal point data EXP EXP ï‚¡
Sub-routine program output off calls FCALL FCALL ï‚¡
Bit device output reverse FF FF ï‚¡
Conversion from BIN 16 data to floating decimal point FLOAT FLT ï‚¡
Reading VRAM data GET OUT SM1255 ï‚´
Section 7.2.3 (8),
(9), (11)
Conversion from hexadecimal ASCII to BIN 16-bit HABIN HABIN ï‚¡
Conversion from ASCII to hexadecimal BIN HEX HEX ï‚¡
ASCII code conversion of designated character strings INPUT OUT SM1255 ï‚´ Section 7.2.3 (11)
Receiving data
INPUT2 OUT SM1255 ï‚´ Section 7.2.3 (9)
INPUT4 OUT SM1255 ï‚´ Section 7.2.3 (9)
Conversion from floating decimal point data to BIN 16 INT INT ï‚¡
Index qualification of a circuit block
IX OUT SM1255 ï‚´ Section 7.2.3 (4)
IXEND OUT SM1255 ï‚´ Section 7.2.3 (4)
Entering data from number keys KEY KEY ï‚´
Detecting character-string length LEN LEN ï‚¡
Upper and lower limit controls for BIN 16-bit data LIMIT LIMIT ï‚¡
Setting the cursor position LOCATE OUT SM1255 ï‚´ Section 7.2.3 (11)
Natural logarithm operations on floating decimal point
data
LOG LOG ï‚¡
Reading word devices in local station LRDP OUT SM1255 ï‚´ Section 7.2.3 (4)
Writing data to word devices in local station LWTP OUT SM1255 ï‚´ Section 7.2.3 (4)
Communication with remote terminal modules MINI OUT SM1255 ï‚´ Section 7.2.3 (10)
Error resetting with remote terminal modules MINIERR OUT SM1255 ï‚´ Section 7.2.3 (10)
Description
AnSCPU QnUCPU
Reference
Instruction name Instruction name Conversion