7 REPLACEMENT OF PROGRAM
7 - 21
Multiplication of floating decimal point data MUL E* ï‚¡
Monitoring PID Control Status PID57 OUT SM1255 ï‚´ Section 7.2.3 (4)
PID control PIDCONT PIDCONT ï‚¡
PID control data setting PIDINIT PIDINIT ï‚¡
Displaying ASCII characters PR OUT SM1255 ï‚´
Section 7.2.3 (7),
(8), (10), (11)
Sending data up to 00
H
code
PR2 OUT SM1255 ï‚´ Section 7.2.3 (9)
PR4 OUT SM1255 ï‚´ Section 7.2.3 (9)
Displaying ASCII characters PRN OUT SM1255 ï‚´
Section 7.2.3 (7),
(8), (10), (11)
Sending designated number of bytes of data
PRN2 OUT SM1255 ï‚´ Section 7.2.3 (9)
PRN4 OUT SM1255 ï‚´ Section 7.2.3 (9)
Writing ASCII characters to the VRAM
PRV OUT SM1255 ï‚´ Section 7.2.3 (11)
PRNV OUT SM1255 ï‚´ Section 7.2.3 (11)
Writing VRAM data PUT OUT SM1255 ï‚´
Section 7.2.3 (8),
(9), (11)
Reading present value
PVRD1 OUT SM1255 ï‚´ Section 7.2.3 (6)
PVRD2 OUT SM1255 ï‚´ Section 7.2.3 (6)
Setting preset data
PVWR1 OUT SM1255 ï‚´ Section 7.2.3 (6)
PVWR2 OUT SM1255 ï‚´ Section 7.2.3 (6)
Conversion from floating decimal point angle to radian RAD RAD ï‚¡
Remote I/O station data read RFRP OUT SM1255 ï‚´ Section 7.2.3 (4)
Changing the extension file register block number RSET OUT SM1255 ï‚´ Section 7.2.3 (4)
Remote I/O station data write RTOP OUT SM1255 ï‚´ Section 7.2.3 (4)
Block addition and subtraction SADD $+ ï‚¡
Comparison between character strings SCMP OUT SM1255 ï‚´ Section 7.2.3 (4)
SIN operation on floating decimal point data SIN SIN ï‚¡
Character string transfers SMOV $MOV ï‚¡
Reading communication status SPBUSY OUT SM1255 ï‚´
Section 7.2.3 (7),
(9), (10)
Forced stop of communication processing SPCLR OUT SM1255 ï‚´
Section 7.2.3 (7),
(9), (10)
Square root operations for floating decimal point data SQR SQR ï‚¡
Reading the display status STAT OUT SM1255 ï‚´ Section 7.2.3 (11)
Conversion from BIN 16-bit to character string STR STR ï‚¡
Subtraction of floating decimal point data SUB E- ï‚¡
Setting comparison reference data
SVWR1 OUT SM1255 ï‚´ Section 7.2.3 (6)
SVWR2 OUT SM1255 ï‚´ Section 7.2.3 (6)
Upper and lower byte exchanges SWAP SWAP ï‚¡
TAN operation on floating decimal point data TAN TAN ï‚¡
Bit test TEST TEST ï‚¡
Linking of random data UNI NUNI ï‚¡
Conversion from character string to BIN 16-bit data VAL VAL ï‚¡
Data dissociation in byte units WTOB WTOB ï‚¡
Link refresh of designated network ZCOM S.ZCOM ï‚¡ Section 7.2.3 (5)
Reading/writing data from/to special function module
in MELSECNET/10 remote I/O station
ZNFR OUT SM1255 ï‚´ Section 7.2.3 (5)
ZNTO OUT SM1255 ï‚´ Section 7.2.3 (5)
Reading from/writing to word devices in the
MELSECNET/10 station
ZNRD J.ZNRD ï‚¡ Section 7.2.3 (5)
ZNWR J.ZNWR ï‚¡ Section 7.2.3 (5)
Zone control for BIN 16-bit data ZONE ZONE ï‚¡
Direct read/write of extension file registers in 1-word
units
ZRRD OUT SM1255 ï‚´ Section 7.2.3 (4)
ZRWR OUT SM1255 ï‚´ Section 7.2.3 (4)
Direct read/write of extension file registers in units of
bytes
ZRRDB OUT SM1255 ï‚´ Section 7.2.3 (4)
ZRWRB OUT SM1255 ï‚´ Section 7.2.3 (4)
Description
AnSCPU QnUCPU
Reference
Instruction name Instruction name Conversion