5 - 87
Chapter 5 Data Used for Positioning Control
[Da.15] Condition target
Set the condition target as required for each control.
Setting value Setting details
01H : Device X
Set the input/output signal ON/OFF as the conditions.
02H : Device Y
03H : Buffer memory (1-word) Set the value stored in the buffer memory as the condition.
03H: The target buffer memory is "1-word (16 bits)"
04H: The target buffer memory is "2-word (32 bits)"
04H : Buffer memory (2-word)
05H : Positioning data No. Select only for "simultaneous start".
[Da.16] Condition operator
Set the condition operator as required for the "[Da.15] Condition target".
[Da.15] Condition target Setting value Setting details
01H: Device X
02H: Device Y
07H : DEV=ON
The state (ON/OFF) of an I/O signal is defined as the
condition. Select ON or OFF as the trigger.
08H : DEV=OFF
03H: Buffer memory (1-word)
04H: Buffer memory (2-word)
01H :

=P1
Select how to use the value (

) in the buffer memory
as a part of the condition.
02H :

P1
03H :

P1
04H :

P1
05H : P1

P2
06H :

P1, P2

[Da.17] Address
Set the address as required for the "[Da.15] Condition target".
[Da.15] Condition target Setting value Setting details
01H : Device X
Not used. (There is no need to set.)
02H : Device Y
03H : Buffer memory (1-word)
Value
(Buffer memory address)
Set the target "buffer memory address".
(For 2 words, set the low-order buffer memory
address.)
04H : Buffer memory (2-word)
05H : Positioning data No. Not used. (There is no need to set.)