9 - 45
Chapter 9 Major Positioning Control
Positioning data setting example
[When "4-axis linear interpolation control (INC linear 4)" is set in positioning data
No. 1 of axis 1]
• Reference axis ............. Axis 1
• Interpolation axis.......... Axis 2, Axis3, Axis4 (The required values are also set in
positioning data No. 1 of axis 2, axis 3 and axis 4.)
Axis
Setting item
Setting example
Setting details
Axis 1
(reference
axis)
Axis 2
(interpolation
axis)
Axis 3
(interpolation
axis)
Axis 4
(interpolation
axis)
Axis 1 Positioning data No. 1
[Da.1] Operation pattern
Positioning
complete
– – –
Set "Positioning complete"
assuming the next positioning data
will not be executed.
[Da.2] Control method
INC
linear 4
– – –
Set incremental system 4-axis
linear interpolation control.
[Da.3]
Acceleration time
No.
1 – – –
Designate the value set in "[Pr.25]
Acceleration time 1" as the
acceleration time at start.
[Da.4]
Deceleration time
No.
0 – – –
Designate the value set in "[Pr.10]
Deceleration time 0" as the
deceleration time at deceleration.
[Da.6]
Positioning
address/
movement
amount
4000.0 m 8000.0 m 4000.0 m 3000.0 m
Set the movement amount.
(Assuming "mm" is set in "[Pr.1]
Unit setting".)
[Da.7] Arc address – – – –
Setting not required (setting value is
ignored).
[Da.8] Command speed
6000.00
mm/min
– – –
Set the speed during movement.
[Da.9]
Dwell time/JUMP
destination
positioning data
No.
500ms – – –
Set the time the machine dwells
after the positioning stop (command
stop) to the output of the positioning
complete signal.
[Da.10]
M code/Condition
data No./Number
of LOOP to LEND
repetitions
10 – – –
Set this when other sub operation
commands are issued in
combination with the No. 1
positioning data.
[Da.20]
Axis to be
interpolated No.1
Axis 2 – – –
Set the axis to be interpolated.
If the self-axis is set, an error will
occur.
[Da.21]
Axis to be
interpolated No.2
Axis 3 – – –
[Da.22]
Axis to be
interpolated No.3
Axis 4 – – –
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.
POINT
When the "reference axis speed" is set during 4-axis linear interpolation control,
set so the major axis side becomes the reference axis. If the minor axis side is set
as the reference axis, the major axis side speed may exceed the "[Pr.8] Speed
limit value".
Refer to Section 9.1.6 "Interpolation control" for the reference axis and
interpolation axis combinations.