9 - 52
Chapter 9 Major Positioning Control
Operation chart
In incremental system 3-axis fixed-feed control, the addresses ([Md.20] Feed
current value) of the current stop position (start addresses) of every axes are set
to "0". Linear interpolation positioning is then carried out from that position to a
position at the end of the movement amount set in "[Da.6] Positioning
address/movement amount". The movement direction is determined by the sign of
the movement amount.
• Positive movement amount .............. Positioning control to forward direction
(Address increase direction)
• Negative movement amount ............. Positioning control to reverse direction
(Address decrease direction)
Designated movement
amount
Designated movement
amount
Md.20
Designated movement amount
Feed current value" of each axisis set to "0" at the positioning start.
(0,0,0)
(0,0,0)
(0,0,0)
Y axis
X axis
Z axis
"

Table of Contents