9 - 54
Chapter 9 Major Positioning Control
Positioning data setting example
[When "3-axis fixed-feed control (fixed-feed 3)" is set in positioning data No. 1 of
axis 1]
• Reference axis ............. Axis 1
• Interpolation axis.......... Axis 2, Axis3 (The required values are also set in
positioning data No. 1 of axis 2 and axis 3.)
Axis
Setting item
Setting example
Setting details
Axis 1
(reference
axis)
Axis 2
(interpolation
axis)
Axis 3
(interpolation
axis)
Axis 1 Positioning data No. 1
[Da.1] Operation pattern
Positioning
complete
– –
Set "Positioning complete"
assuming the next positioning
data will not be executed.
[Da.2] Control method Fixed-feed 3
Set 3-axis fixed-feed control.
[Da.3]
Acceleration time
No.
1 – –
Designate the value set in
"[Pr.25] Acceleration time 1" as
the acceleration time at start.
[Da.4]
Deceleration time
No.
0 – –
Designate the value set in
"[Pr.10] Deceleration time 0" as
the deceleration time at
deceleration.
[Da.6]
Positioning
address/
movement amount
10000.0 m 5000.0 m 6000.0 m
Set the positioning address.
(Assuming "mm" is set in "[Pr.1]
Unit setting".)
[Da.7] Arc address
Setting not required (setting
value is ignored).
[Da.8] Command speed
6000.00
mm/min
– –
Set the speed during
movement.
[Da.9]
Dwell time/JUMP
destination
positioning data
No.
500ms –
Set the time the machine dwells
after the positioning stop
(command stop) to the output of
the positioning complete signal.
[Da.10]
M code/Condition
data No./Number
of LOOP to LEND
repetitions
10 –
Set this when other sub
operation commands are
issued in combination with the
No. 1 positioning data.
[Da.20]
Axis to be
interpolated No.1
Axis 2
Set the axis to be interpolated.
If the self-axis is set, an error
will occur.
[Da.21]
Axis to be
interpolated No.2
Axis 3
[Da.22]
Axis to be
interpolated No.3
– – –
Setting not required (setting
value is ignored).
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.