6. NORMAL GAIN ADJUSTMENT
6 - 9
(g) Clearing one-touch tuning
You can clear the parameter values set with one-touch tuning.
Refer to table 6.1 for the parameters which you can clear.
Pushing "Return to before tuning" in the one-touch tuning window of MR Configurator2 enables to
rewrite the parameter to the value before pushing the start button.
In addition, pushing "Return to initial value" in the one-touch tuning window enables to rewrite the
parameter to the initial value.
Clearing one-touch tuning is completed, the following window will be displayed. (returning to initial
value)