EasyManua.ls Logo

Mitsubishi Electric MELSERVO-J5 HK-KT43W - The Graph of Overload Protection Characteristics of Rotary Servo Motor; Characteristics of Electromagnetic Brake

Mitsubishi Electric MELSERVO-J5 HK-KT43W
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
116
6 HK-KT SERIES
6.2 The graph of overload protection characteristics of rotary servo motor
6.2 The graph of overload protection characteristics
of rotary servo motor
Overload protection of rotary servo motors has been enhanced for MR-J5 servo amplifiers with firmware version A7 or later.
Refer to "Overload protection characteristics" in the following manual.
MR-J5 User's Manual (Hardware)
6.3 Characteristics of electromagnetic brake
Before operating the servo motor, confirm that the electromagnetic brake operates properly.
The operation time of the electromagnetic brake varies depending on the power supply circuit being used.
Check the operation delay time with an actual machine.
The characteristics of the electromagnetic brake provided for the rotary servo motor with an electromagnetic brake are shown
below.
*1 This type does not have a manual release mechanism. Use a 24 V DC power supply to release the brake electrically.
*2 The value for initial on gap at 20 °C.
*3 Brake lining wear due to braking will increase the brake gap, but the gap is not adjustable. Therefore, the brake life indicates the number
of times the brake can be applied before gap adjustment becomes necessary.
*4 Prepare a power supply exclusively for the electromagnetic brake.
*5 The values are design values. These are not the guaranteed values.
*6 Select the electromagnetic brake control relay properly, in consideration of the characteristics of the electromagnetic brake and surge
absorber. When a diode is used as a surge absorber, the electromagnetic braking time becomes longer.
*7 The value of the brake static friction torque is the lower limit in the initial state at 20 °C.
Item HK-KT053WB
HK-KT13WB
HK-
KT1M3WB
HK-
KT13UWB
HK-KT23WB
HK-
KT43(4)WB
HK-
KT63(4)WB
HK-
KT23UWB
HK-
KT43UWB
HK-
KT7M3(4)WB
HK-
KT103(4)WB
HK-
KT7M3UWB
HK-
KT103UWB
HK-
KT153(4)WB
HK-
KT203(4)WB
HK-
KT202(4)WB
Type
*1
Spring actuated type safety brake
Rated voltage
*4
24 V DC (-10 % to 0 %)
Power consumption at 20 °C [W] 6.4 7.9 8.2 10 9.0 13.8
Coil resistance
*6
[] 917370576442
Inductance
*6
[H] 0.140.200.190.160.230.15
Brake static friction torque
*7
[N•m] 0.48 or more 1.9 or more 1.3 or more 3.2 or more 3.2 or more 9.5 or more
Release delay time
*2
[s] 0.030.030.030.040.030.09
Braking delay time
[s]
DC off
*2
0.01 0.02 0.02 0.02 0.03 0.03
Permissible
braking work [J]
Per braking 5.6 22 22 64 66 64
Per hour 56 220 220 640 660 640
Brake looseness at servo motor shaft
*5
[degree]
2.51.20.90.90.90.9
Brake life
*3
Number of braking
times [times]
20000 20000 20000 20000 20000 5000
Work per braking [J] 5.6 22 22 64 33 64
Selection example
of surge
absorbers to be
used
*6
For the suppressed
voltage 125 V
TND20V-680KB (Manufactured by NIPPON CHEMI-CON CORPORATION)
For the suppressed
voltage 350 V
TND10V-221KB (Manufactured by NIPPON CHEMI-CON CORPORATION)

Table of Contents