84
5 WIRING OPTION
5.3 Encoder cable
CN2, CN2A, CN2B, and CN2C side connector (1)
The following shows the view from the wiring side. Do not connect anything to the pins that are marked with a diagonal line.
Securely connect the external conductor of the shielded cable to the ground plate and fix it to the connector shell.
Page 99 Shielding CN2, CN2A, CN2B, and CN2C connectors
Receptacle: 36210-0100PL
Shell kit: 36310-3200-008
(3M or equivalent)
Connector set: 54599-1016
(Molex)
Junction connector (2)
The following shows the view from the wiring side.
Plug (DDK)
Straight plug Socket contact
CMV1-SP10S-M2 CMV1-#22ASC-S1-100
Applicable wire size:
AWG 20 or lower
4
2
8
6
1
5
10
3
7
9
MRR
LG
P5
MR
P5 MR
MRR
LG
13 79
428610
5
1
MR
2
MRR
3
5
LG
476
10
SHD
98
P5

Table of Contents