6 OPTIONS AND PERIPHERAL EQUIPMENT
6.4 FR-XC multifunction regeneration converter
189
6
Fuses (between P/+ and P4, between N/- and N-)
The table below lists the recommended fuses to install between the FR-XC and servo amplifier(s).
*1 Manufacturer: Mersen Fma Japan KK
Service inquiries: Sun-wa Technos Corp.
Molded-case circuit breakers/earth-leakage current breakers and magnetic contactors
Recommended molded-case circuit breakers/earth-leakage current breakers and magnetic contactors are listed in the table
below.
■200 V class
*1 Models in parentheses can be used when the rated capacity of multifunction regeneration converter total capacity of connected servo
amplifiers × 2.
Servo amplifier capacity [kW] 200 V class
Fuse rating [A] Model
*1
0.1 20 6.900CPGR10.38 0020
0.2 20 6.900CPGR10.38 0020
0.4 25 6.900CPGR10.38 0025
0.6 25 6.900CPGR10.38 0025
0.75 30 6.900CPGR10.38 0030
1 32 6.900CPGR10.38 0032
2 63 6.9URD30TTF 0063
3.5 80 6.9URD30TTF 0080
5 160 6.9URD30TTF 0160
7 200 6.9URD30TTF 0200
Item FR-XC-_
7.5K 11K 15K 22K 30K 37K 55K
Molded-case circuit breaker
or earth-leakage current
breaker
*1
100AF 60A
(30AF 30A)
100AF 75A
(50AF 50A)
225AF 125A
(100AF 75A)
225AF 175A
(100AF 100A)
225AF 225A
(125AF 125A)
400AF 250A
(125AF 125A)
400AF 400A
(225AF 175A)
Magnetic contactor
*1
S-T35
(S-T21)
S-T50
(S-T35)
S-T65
(S-T50)
S-T100
(S-T65)
S-N125
(S-T80)
S-N150
(S-T100)
S-N220
(S-N125)