10 USING A LINEAR SERVO MOTOR
10.4 Basic functions
339
10
Absolute position linear encoder
The reference home position using an absolute position linear encoder is per 1048576 pulses based on the linear encoder
home position (absolute position data = 0). The stop intervals at homing can be changed with [Pr. PL01.2 Homing stop
interval setting]. For the specifications of the stop intervals at homing, refer to the following.
Page 338 Incremental linear encoder
The specifications are the same as the ones when an incremental encoder is used.