EasyManua.ls Logo

Mitsubishi Electric MELSERVO-JN Series - 1. Operation and setting

Mitsubishi Electric MELSERVO-JN Series
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 2 -
Introduction
1. Operation and setting
Operation and settings of the servo amplifier are easily performed only on the display section (3-digit, 7-
segment LED) and on the operation section (four pushbuttons and one-touch tuning button) located on the
front panel of the servo amplifier.
AUTO
MODE
UP/DOWN
SET
Scrolls the display and data.
Determines the display and
data, and clears data.
Changes the display mode
and switches the upper/lower.
Executes the one-touch
tuning.
(1) One-touch tuning function (refer to section 6.1)
Gain and filter adjustment of the servo is easily made by the AUTO button located on the front panel of the
servo amplifier.
(2) Status display, diagnosis, and parameter setting (refer to chapter 5)
The servo amplifier status display (cumulative feedback pulses, servo motor speed, and others), diagnosis
(servo operation-ready complete status, external I/O signal ON/OFF, test operation), point table settings
and parameter settings can be easily performed by the MODE, SET, UP and DOWN buttons located on the
front panel of the servo amplifier.

Table of Contents