EasyManua.ls Logo

Mitsubishi Electric MELSERVO-JN Series - 4.1.11 Selection of command input pulse form

Mitsubishi Electric MELSERVO-JN Series
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 - 14
4. PARAMETERS
4.1.11 Selection of command input pulse form
Parameter
Initial
value
Setting
range
Unit
Control mode
No. Symbol Name Position
Internal
speed
Internal
torque
PA13 *PLSS Command input pulse form 000h
Refer to
the text.
POINT
This parameter is made valid when power is switched off, then on after setting.
The noise tolerance can be enhanced by setting parameter No. PA13 to "1 "
when the command pulse frequency is 500kpps or less or "2
" when
200kpps or less.
Select the input form of the pulse train input signal. Command pulses may be input in any of three different
forms, for which positive or negative logic can be chosen.
Arrow
or in the table indicates the timing of importing a pulse train.
A- and B-phase pulse trains are imported after being multiplied by 4.
Signed pulse
train
Forward rotation
pulse train
Reverse rotation
pulse train
Selection of command input pulse form
Parameter No. PA13
Setting
00
01
Pulse train input filter selection
Pulse train form
Forward rotation command Reverse rotation command
Signed pulse
train
A-phase pulse
train
B-phase pulse
train
Forward rotation
pulse train
Reverse rotation
pulse train
A-phase pulse
train
B-phase pulse
train
02
10
12
Positive logic
NP
PP
PP
L
H
NP
PP
NP
NP
PP
L
H
PP
NP
PP
NP
Setting
0
1Mpps or less
1
500kpps or less
2
200kpps or less
Negative logic
11
Command pulse frequency

Table of Contents

Related product manuals