4 - 30
4. PARAMETERS
4.3 Extension setting parameters (No. PC
)
POINT
For any parameter whose symbol is preceded by *, set the parameter value and
switch power off once, then switch it on again to make that parameter setting
valid.
Set any parameter with [Applied] written in the name column when using an
advanced function.
4.3.1 Parameter list
No. Symbol Name
Initial
value
Unit
Control mode
Position
Internal
speed
Internal
torque
PC01 STA
Acceleration time constant
0 ms
PC02 STB
Deceleration time constant
0 ms
PC03 STC
S-pattern acceleration/deceleration time constant
0 ms
PC04 TQC
Torque command time constant
0 ms
PC05 SC0
Internal speed command 0
0 r/min
Internal speed limit 0
PC06 SC1
Internal speed command 1
100 r/min
Internal speed limit 1
PC07 SC2
Internal speed command 2
500 r/min
Internal speed limit 2
PC08 SC3
Internal speed command 3
1000 r/min
Internal speed limit 3
PC09 MBR
Electromagnetic brake sequence output
100 ms
PC10 ZSP
Zero speed
50 r/min
PC11 *BPS
Alarm history clear
000h
PC12 TC
Internal torque command
0.0
%
PC13 *ENRS
Encoder output pulses selection
000h
PC14 TL2
Internal torque limit 2
[Applied]
100 %
PC15 ERZL
Error excessive alarm detection level
3.0
rev
PC16
For manufacturer setting
3.0
PC17 *OSL
Overspeed alarm detection level
0 r/min
PC18
For manufacturer setting
1000
PC19
0
PC20
000h
PC21
001h
PC22 *COP1
Function selection C-1
[Applied]
000h
PC23 *COP2
Function selection C-2
[Applied]
000h
PC24 *COP3
Function selection C-3
[Applied]
000h
PC25 *COP4
Function selection C-4
[Applied]
000h
PC26 ALDT
Detailed setting of overload tough drive
[Applied]
200
10ms
PC27 OSCL
Detailed setting of vibration tough drive
[Applied]
50 %
PC28 CVAT
Detailed setting of instantaneous power failure tough drive
[Applied]
3
10ms
PC29 *COP5
Function selection C-5
[Applied]
000h
PC30 *COP6
Function selection C-6
[Applied]
000h
PC31 SC4
Internal speed command 4
[Applied]
200 r/min
Internal speed limit 4
[Applied]
PC32 SC5
Internal speed command 5
[Applied]
300 r/min
Internal speed limit 5
[Applied]